Data Center Backup Battery UPS

Data Center 4U Integrated UPS 12V 450AH 5000WH

Data Center 4U Integrated UPS 12V 450AH 5000WH

Data center 4U integrated UPS 12V 450Ah 5000WH One: packaging Two: noted 1. This product contains lithium battery, please stay away from fire source, if not use please do special treatment, do not throw away at will. 2. Can't use this product in the humid environment or water, pay attention......
Chat Now

Data center 4U integrated UPS 12V 450Ah 5000WH

 

No.

Item

General Parameter

Remark

1.1

Description

Heavy Duty AGV battery 9.6kWh 48V   Capacity 200Ah with RS485 protocol

15S60P Assembly

1.2

Cell Model

26650-3200mAh


1.3

Typical Capacity

450Ah


1.4

Typical Voltage

12V


1.5

End of Charge Voltage

54.75V


1.6

Charge Current

0.2C


1.7

Charging time

5-6 Hours


1.8

End discharge Voltage 

30.0V


1.9

Max continuous charge current

100A


2.0

Maximum Continuous Discharging Current

135A


2.1

Over-discharge Voltage Protection   cell 

2V


2.2

Over-Current Discharge Protection

400A


2.3

Short circuit protection

With BMS

RS485 protocol

2.4

Dimension

46x44x18cm


2.5

Weight

36kg


2.6

Operation Temperature Range

Charge 0~45 C, Discharge -20~60 C



image001.jpg


One: packaging

 

NO

name

QTY

1

UPS device

1

2

AC cable

1

3

User nanual

1

4

QA certificate

1

5

LED light 24V   5W(option)

2

6

Solar panel 24V ≤ 800W(option)

1

 

image003.jpg

 

Two:  noted

1.  This product contains lithium battery, please stay away from fire source, if not use please do special treatment, do not throw away at will. 

2.  Can't use this product in the humid environment or water, pay attention to moisture proof, as far as possible in ventilation, dry environment. 

3.  When using products, please gently release, do not drop, knock or violent disassemble. 

4.  It is found that there are abnormal phenomena of smoke or fire in the use of the machine. Please stop using it immediately and take relevant measures to prevent the explosion. 

5.  When using this product, please turn on the switch and turn on the corresponding switch. The LED indicator light will highlight the output and use it again. 

6.  When using this product for the first time, please re-charge the battery after all the battery has been released. 

7.  When the product is idle, please take it out every three months or so to ensure battery life.

Hot Tags: data center 4u integrated UPS 12V 450AH 5000wh, China, suppliers, manufacturers, factory